CWL Limit Switch
Features
Contact Form
>> Download PDF (393KB)
Ratings
Rated Voltage | Noninductive Load (A) | Inductive Load (A) | ||||||
Resistance Load | Lamp Load | Inductive Load | Motor Load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125VAC 250VAC 480VAC 600VAC |
10 5 3 1 |
3 2 1.5 1 |
1.5 1 0.8 0.5 |
10 5 3 1.5 |
5 3 1.5 1 |
2.0 1.0 0.8 0.5 |
||
8VDC 14VDC 30VDC 125VDC 250VDC |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
3 3 3 0.2 0.1 |
10 10 6 0.8 0.4 |
6 6 4 0.2 0.1 |
Characteristics
Operation speed | 1mm-2m/sec |
Operating frequency | Mechanical: 120 operations/minute, Electrical: 30 operations/minute |
Contact resistance | 25mΩ max. (initial value) |
Insulation resistance | 100mΩ min. (at 500VDC) |
Dielectric strength | 1000VAC, 50/60HZ for 1 minute between terminals of the same polarity |
1500VAC, 50/60 HZ for 1 minute between currentcarrying and non-current-carrying metal parts |
|
1500VAC, 50/60 HZ for 1 minute between each terminal and ground | |
Vibration | 10-55HZ,1.5mm double amplitude |
Shock | Mechanical durable: 1, 000m/Sec2 (about 100G'S) Malfunction: 300m/Sec2 (about 30G'S) |
Ambient temperature | -10℃ to +80℃ |
Humidity | <95% RH |
Life | Mechanical: 15,000,000 operations above (under rated OT) Electrical: 500,000 operations above |
Weight | About 275g |
Degree of protection | IP67 |
Operating characteristics
Models | CWLCA2-2 | CWLD2 | CWLNJ | CWLNJ-S2 | CWLCA12-2-Q | CWLCL | CWLCA32-41 | CWLD | CWLNJ-2 | CWLNJ-30 | CWLD1 |
OF Max. | 1360g | 2720g | 150g | 29g | 1360g | 142g | 1200g | 2720g | 120g | 80g | 2720g |
RF Min. | 227g | 910g | - | - | 227g | 28g | - | 910g | - | - | 910g |
PT Max. | 20 º | 1.7mm | 28mm | 28mm | 20 º | 20 º | 55 º | 1.7mm | 28mm | 28mm | 1.7mm |
OT Min. | 30 º | 5.6mm | - | - | 30 º | 30 º | 35 º | 6.4mm | - | - | 5.6mm |
MD Max. | 12 º | 1mm | - | - | 12 º | 12 º | - | 1mm | - | - | 1mm |
TF Max. | 2720g | - | - | - | 2720g | 200g | - | - | - | - | 2720g |
TT Min. | 50 º | 6.5±0.8mm | - | - | 50 º | 50 º | OP:90±10 º | OP:34±2.8mm | - | - | 6.5±0.8mm |