Fan & Fan Filter
FK55
Application
-
Extra-thin ventilation filter edge adding the high-grade fluid sealant can prevent the rainwater entering the control cabinet along the filter from the holing place. Especially the surface leaf bar, with the arc structure, can prevent the rainwater entering, Adhesive bonded fiber filter pad can be used to prevent over 10 microns dust granule. Extra-thin leaf bar thickness bulges only 4~6mm, which largely raises its beautiful degree. Installation need not screw, only inlay. Its protection grade can reach IP54.
Technical Data

Fand Filter Type FK | 5522.230 | 5522.115 | 5522.024 |
Working Voltage V/H | 230/50/60 | 115/50/60 | 24(DC) |
Air flow, free blowing | 55/66m3/h | ||
Flux of air equip filter exproted include filtering pad of standard | 1xFK 5522.300; 43/50m3/h 2xFK 5522.300; 48/55m3/h 1xFK 5522.300; 48/55m3/h |
||
Axial Fan | Self-start screened magnetic pole motor | Direct current motor | |
Rated Current | 0.12/0.11A | 0.24/0.23A | 0.15A |
Power | 19W/18W | 3.5W | |
Noise level | 46/49dB(A) | ||
Scope of temperature | -10°C ~ 55°C | ||
Exit Filter Type FK | 5522.300 |
Dimensioned
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |

Fand Filter Type FK | 5523.230 | 5523.115 | 5523.024 |
Working Voltage V/H | 230/50/60 | 115/50/60 | 24(DC) |
Air flow, free blowing | 105/120m3/h | ||
Flux of air equip filter exproted include filtering pad of standard | 1xFK 5523.200; 71/82m3/h 2xFK 5523.200; 85/98m3/h 1xFK 5523.200; 78/90m3/h |
||
Axial Fan | Self-start screened magnetic pole motor | Direct current motor | |
Rated Current | 0.12/0.11A | 0.24/0.23A | 0.15A |
Power | 19W/18W | 3.5W | |
Noise level | 46/49dB(A) | ||
Scope of temperature | -10°C ~ 55°C | ||
Exit Filter Type FK | 5523.300 |
Dimensioned
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |

Fand Filter Type FK | 5525.230 | 5525.115 | 5525.024 |
Working Voltage V/H | 230/50/60 | 115/50/60 | 24(DC) |
Air flow, free blowing | 230/265m3/h | ||
Flux of air equip filter exproted include filtering pad of standard | 1xFK 5525.200; 170/205m3/h 2xFK 5525.200; 200/230m3/h 1xFK 5525.200; 190/215m3/h |
||
Axial Fan | Self-start screened magnetic pole motor | Direct current motor | |
Rated Current | 0.28/0.24A | 0.53/0.49A | 0.58A |
Power | 41W/38W | 14W | |
Noise level | 54/56dB(A) | ||
Scope of temperature | -10°C ~ 55°C | ||
Exit Filter Type FK | 5525.300 |
Dimensioned
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |

Fand Filter Type FK | 5526.230 | 5526.115 |
Working Voltage V/H | 230/50/60 | 115/50/60 |
Air flow, free blowing | 500/560m3/h | |
Flux of air equip filter exproted include filtering pad of standard | 1xFK 5526.200; 360/390m3/h 2xFK 5526.200; 440/495m3/h |
|
Axial Fan | Capacitance electromotion | |
Rated Current | 0.29/0.35A | 0.58/0.70A |
Power | 64W/80W | |
Noise level | 59/61dB(A) | |
Scope of temperature | -10°C ~ 55°C | |
Exit Filter Type FK | 5526.300 |
Dimensioned
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |